概要
Linux/Unix 主機上安裝的一個或多個套件存有弱點,供應商表示將不會修補。
說明
Linux/Unix 主機上安裝了一個或多個受到弱點影響的套件,且供應商未提供可用的修補程式。
- 在 Linux 核心中,已解決下列弱點: igc: avoid returning frame twice in XDP_REDIRECT When a frame can not be transmitted in XDP_REDIRECT (e.g. due to a full queue), it is necessary to free it by calling xdp_return_frame_rx_napi. However, this is the responsibility of the caller of the ndo_xdp_xmit (see for example bq_xmit_all in kernel/bpf/devmap.c) and thus calling it inside igc_xdp_xmit (which is the ndo_xdp_xmit of the igc driver) as well will lead to memory corruption. In fact, bq_xmit_all expects that it can return all frames after the last successfully transmitted one.
Therefore, break for the first not transmitted frame, but do not call xdp_return_frame_rx_napi in igc_xdp_xmit. This is equally implemented in other Intel drivers such as the igb. There are two alternatives to this that were rejected: 1. Return num_frames as all the frames would have been transmitted and release them inside igc_xdp_xmit. While it might work technically, it is not what the return value is meant to represent (i.e. the number of SUCCESSFULLY transmitted packets). 2. Rework kernel/bpf/devmap.c and all drivers to support non-consecutively dropped packets. Besides being complex, it likely has a negative performance impact without a significant gain since it is anyway unlikely that the next frame can be transmitted if the previous one was dropped. The memory corruption can be reproduced with the following script which leads to a kernel panic after a few seconds. It basically generates more traffic than a i225 NIC can transmit and pushes it via XDP_REDIRECT from a virtual interface to the physical interface where frames get dropped. #!/bin/bash INTERFACE=enp4s0 INTERFACE_IDX=`cat /sys/class/net/$INTERFACE/ifindex` sudo ip link add dev veth1 type veth peer name veth2 sudo ip link set up $INTERFACE sudo ip link set up veth1 sudo ip link set up veth2 cat << EOF > redirect.bpf.c SEC(prog) int redirect(struct xdp_md *ctx) { return bpf_redirect($INTERFACE_IDX, 0); } char _license[] SEC(license) = GPL; EOF clang -O2 -g -Wall -target bpf -c redirect.bpf.c -o redirect.bpf.o sudo ip link set veth2 xdp obj redirect.bpf.o cat << EOF > pass.bpf.c SEC(prog) int pass(struct xdp_md *ctx) {return XDP_PASS; } char _license[] SEC(license) = GPL; EOF clang -O2 -g -Wall -target bpf -c pass.bpf.c -o pass.bpf.o sudo ip link set $INTERFACE xdp obj pass.bpf.o cat << EOF > trafgen.cfg { /* Ethernet Header */ 0xe8, 0x6a, 0x64, 0x41, 0xbf, 0x46, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF, 0xFF, const16(ETH_P_IP), /* IPv4 Header */ 0b01000101, 0, # IPv4 version, IHL, TOS const16(1028), # IPv4 total length (UDP length + 20 bytes (IP header)) const16(2), # IPv4 ident 0b01000000, 0, # IPv4 flags, fragmentation off 64, # IPv4 TTL 17, # Protocol UDP csumip(14, 33), # IPv4 checksum /* UDP Header */ 10, 0, 1, 1, # IP Src - adapt as needed 10, 0, 1, 2, # IP Dest - adapt as needed const16(6666), # UDP Src Port const16(6666), # UDP Dest Port const16(1008), # UDP length (UDP header 8 bytes + payload length) csumudp(14, 34), # UDP checksum /* Payload */ fill('W', 1000), } EOF sudo trafgen -i trafgen.cfg -b3000MB
-o veth1 --cpp (CVE-2024-26853)
請注意,Nessus 依賴供應商報告的套件存在。
Plugin 詳細資訊
檔案名稱: unpatched_CVE_2024_26853.nasl
代理程式: unix
支援的感應器: Nessus Agent, Nessus
風險資訊
媒介: CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C
媒介: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
時間媒介: CVSS:3.0/E:U/RL:O/RC:C
弱點資訊
必要的 KB 項目: Host/local_checks_enabled, Host/cpu, global_settings/vendor_unpatched
可輕鬆利用: No known exploits are available