| 65656 | Honeywell 多個產品 HscRemoteDepoy.dll ActiveX 控制項任意程式碼執行 | Nessus | SCADA | 2026/7/17 | medium |
| 65602 | Schneider Electric Accutech Manager 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 64788 | 惡意程序偵測:遭竊的 Bit9 憑證所簽署的惡意程式碼 | Nessus | Windows | 2026/7/17 | critical |
| 64687 | 惡意程序偵測:執行的 APT1 軟體 | Nessus | Windows | 2026/7/17 | critical |
| 64683 | Siemens SIMATIC RF-MANAGER KeyHelp.ocx 緩衝區溢位 | Nessus | SCADA | 2026/7/17 | medium |
| 64682 | Siemens SIMATIC RF-MANAGER 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 63619 | Windows 作業系統部分產品金鑰 (WMI) | Nessus | Windows | 2026/7/17 | info |
| 63429 | Siemens Automation License Manager 'almaxcx.dll' ActiveX 任意檔案覆寫弱點 | Nessus | SCADA | 2026/7/17 | medium |
| 63427 | Siemens Automation License Manager 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 62964 | IOServer 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 61797 | WMI 防火牆規則列舉 | Nessus | Windows | 2026/7/17 | info |
| 61646 | Oracle Integrated Lights Out Manager 預設認證 | Nessus | Misc. | 2026/7/17 | critical |
| 61394 | Windows 目錄上的 nginx 別名存取限制繞過 | Nessus | Web Servers | 2026/7/17 | medium |
| 60084 | Advantech Studio ISSymbol ActiveX 控制項多個緩衝區溢位弱點 | Nessus | SCADA | 2026/7/17 | high |
| 60083 | Advantech Studio 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 60023 | ActiveSync 資料收集 | Nessus | Mobile Devices | 2026/7/17 | info |
| 59892 | WellinTech KingHistorian 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 59643 | MS12-040:Microsoft Dynamics AX Enterprise Portal 中的一個弱點可允許權限提升 (MSSQL 檢查) | Nessus | Windows : Microsoft Bulletins | 2026/7/17 | medium |
| 59641 | 惡意程序偵測:可能不需要的軟體 | Nessus | Windows | 2026/7/17 | info |
| 59558 | Measuresoft ScadaPro < 4.0.1.0 service.exe 多個弱點 (經認證的檢查) | Nessus | SCADA | 2026/7/17 | critical |
| 59556 | Measuresoft ScadaPro 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 59502 | WellinTech KingSCADA 3.1 < 2012-04-16 user.db Base-64 編碼本機認證洩漏 | Nessus | SCADA | 2026/7/17 | high |
| 59501 | WellinTech KingSCADA 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 59500 | WellinTech KingOPCServer 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 59377 | WellinTech KingView 6.53 < 2012-03-22 多個弱點 | Nessus | SCADA | 2026/7/17 | critical |
| 59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll 模組 Op-code 3 封包剖析遠端溢位 | Nessus | SCADA | 2026/7/17 | critical |
| 59375 | WellinTech KingView 6.53 < 2010-12-15 HistorySvr.exe TCP 要求遠端溢位 | Nessus | SCADA | 2026/7/17 | critical |
| 59374 | WellinTech KingView 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 59275 | 惡意處理程序偵測 | Nessus | Windows | 2026/7/17 | critical |
| 58991 | RuggedCom RuggedOS 預設 'factory' 帳戶後門程式 | Nessus | SCADA | 2026/7/17 | critical |
| 58902 | MS12-026:Forefront Unified Access Gateway (UAG) 中的多個弱點可允許資訊洩漏 (2663860) (未經認證的檢查) | Nessus | Web Servers | 2026/7/17 | medium |
| 58796 | Microsys PROMOTIC 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 58750 | nginx 1.0.7 - 1.0.14 / 1.1.3 - 1.1.18 ngx_http_mp4_module 緩衝區溢位 | Nessus | Web Servers | 2026/7/17 | medium |
| 58515 | HP Network Node Manager 偵測 | Nessus | CGI abuses | 2026/7/17 | info |
| 58451 | 7-Technologies TERMIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2026/7/17 | high |
| 58450 | 7-Technologies TERMIS 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 58449 | 7-Technologies AQUIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2026/7/17 | high |
| 58448 | 7-Technologies AQUIS 偵測 | Nessus | SCADA | 2026/7/17 | info |
| 58414 | nginx < 1.0.14 / 1.1.17 HTTP 標頭回應記憶體洩漏 | Nessus | Web Servers | 2026/7/17 | medium |
| 58413 | nginx < 1.0.10 ngx_resolver_copy 函式 DNS 回應剖析緩衝區溢位 | Nessus | Web Servers | 2026/7/17 | medium |
| 58327 | Samba「AndX」要求堆積式緩衝區溢位 | Nessus | Misc. | 2026/7/17 | critical |
| 58186 | 修補程式管理:SCCM 報告 | Nessus | Misc. | 2026/7/17 | info |
| 57849 | IBM iSeries 快取密碼 | Nessus | Windows | 2026/7/17 | low |
| 57030 | 修補程式管理:遺漏來自 SCCM 的更新 | Nessus | Misc. | 2026/7/17 | info |
| 57029 | 修補程式管理:SCCM 伺服器設定 | Nessus | Settings | 2026/7/17 | info |
| 56995 | Advantech / BroadWin WebAccess webvrpcs.exe 服務遠端程式碼執行 (未經認證的檢查) (過時) | Nessus | SCADA | 2026/7/17 | critical |
| 56994 | Advantech / BroadWin WebAccess webvrpcs.exe 服務遠端程式碼執行 (經認證的檢查) | Nessus | SCADA | 2026/7/17 | critical |
| 56993 | Advantech / BroadWin WebAccess Client「bwocxrun.ocx」多個遠端弱點 | Nessus | SCADA | 2026/7/17 | high |
| 56467 | 上次開機時間 (WMI) | Nessus | Windows | 2026/7/17 | info |
| 55926 | Citrix EdgeSight Load Tester (ESLT) 版本偵測 | Nessus | Service detection | 2026/7/17 | info |