| 58902 | MS12-026:Forefront Unified Access Gateway (UAG) 中的多個弱點可允許資訊洩漏 (2663860) (未經認證的檢查) | Nessus | Web Servers | 2026/4/8 | medium |
| 58796 | Microsys PROMOTIC 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 58515 | HP Network Node Manager 偵測 | Nessus | CGI abuses | 2026/4/8 | info |
| 58451 | 7-Technologies TERMIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2026/4/8 | high |
| 58450 | 7-Technologies TERMIS 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 58449 | 7-Technologies AQUIS 不明路徑 Subversion 任意 DLL 插入程式碼執行 | Nessus | SCADA | 2026/4/8 | high |
| 58448 | 7-Technologies AQUIS 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 58327 | Samba「AndX」要求堆積式緩衝區溢位 | Nessus | Misc. | 2026/4/8 | critical |
| 58186 | 修補程式管理:SCCM 報告 | Nessus | Misc. | 2026/4/8 | info |
| 57849 | IBM iSeries 快取密碼 | Nessus | Windows | 2026/4/8 | low |
| 57848 | IBM iSeries 預設密碼 | Nessus | Misc. | 2026/4/8 | critical |
| 57847 | IBM iSeries Server 偵測 | Nessus | Service detection | 2026/4/8 | info |
| 57400 | VMware vSphere 安裝的 VIB | Nessus | VMware ESX Local Security Checks | 2026/4/8 | info |
| 57399 | VMware vSphere 已安裝的修補程式 | Nessus | VMware ESX Local Security Checks | 2026/4/8 | info |
| 57398 | VMware 的停用虛擬機器 | Nessus | VMware ESX Local Security Checks | 2026/4/8 | info |
| 57397 | VMware 作用中的虛擬機器 | Nessus | VMware ESX Local Security Checks | 2026/4/8 | info |
| 57396 | VMware vSphere 偵測 | Nessus | Service detection | 2026/4/8 | info |
| 57032 | 修補程式管理:遺漏來自 WSUS 的更新 | Nessus | Misc. | 2026/4/8 | info |
| 57031 | 修補程式管理:WSUS 伺服器設定 | Nessus | Settings | 2026/4/8 | info |
| 57030 | 修補程式管理:遺漏來自 SCCM 的更新 | Nessus | Misc. | 2026/4/8 | info |
| 57029 | 修補程式管理:SCCM 伺服器設定 | Nessus | Settings | 2026/4/8 | info |
| 56995 | Advantech / BroadWin WebAccess webvrpcs.exe 服務遠端程式碼執行 (未經認證的檢查) (過時) | Nessus | SCADA | 2026/4/8 | critical |
| 56994 | Advantech / BroadWin WebAccess webvrpcs.exe 服務遠端程式碼執行 (經認證的檢查) | Nessus | SCADA | 2026/4/8 | critical |
| 56993 | Advantech / BroadWin WebAccess Client「bwocxrun.ocx」多個遠端弱點 | Nessus | SCADA | 2026/4/8 | high |
| 56467 | 上次開機時間 (WMI) | Nessus | Windows | 2026/4/8 | info |
| 55926 | Citrix EdgeSight Load Tester (ESLT) 版本偵測 | Nessus | Service detection | 2026/4/8 | info |
| 55630 | Sielco Sistemi Winlog 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 55472 | 裝置主機名稱 | Nessus | General | 2026/4/8 | info |
| 55438 | SMB:在掃描後停用 C$ 與 ADMIN$ 共用 (WMI) | Nessus | Settings | 2026/4/8 | info |
| 55437 | SMB:在掃描期間啟用 C$ 與 ADMIN$ 共用 (WMI) | Nessus | Settings | 2026/4/8 | info |
| 55286 | MS11-048:SMB 伺服器中的弱點可允許拒絕服務 (2536275) (遠端檢查) | Nessus | Windows | 2026/4/8 | high |
| 53572 | 自動化解決方案 Modbus/TCP OPC 伺服器偵測 | Nessus | SCADA | 2026/4/8 | info |
| 53548 | Ecava IntegraXor 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 53223 | RealFlex Technologies RealWin 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 52992 | Movicon SCADA/HMI 軟體偵測 | Nessus | SCADA | 2026/4/8 | info |
| 52961 | 7-Technologies / Schneider-Electric IGSS 偵測 | Nessus | SCADA | 2026/4/8 | info |
| 52051 | Moxa Device Manager Tool MDM2_Gateway 回應遠端溢位 | Nessus | SCADA | 2026/4/8 | high |
| 52001 | WMI QuickFixEngineering (QFE) 列舉 | Nessus | Windows | 2026/4/8 | info |
| 51902 | Microsoft System Center Configuration Manager 資料庫資訊 | Nessus | Windows | 2026/4/8 | info |
| 51360 | Ecava IntegraXor ActiveX 的儲存方法有緩衝區溢位 | Nessus | SCADA | 2026/4/8 | high |
| 51187 | WMI 可加密磁碟區列舉 | Nessus | Windows | 2026/4/8 | info |
| 51186 | WMI 信賴平台模組列舉 | Nessus | Windows | 2026/4/8 | info |
| 49694 | BACnet OPC Client < 1.0.25 緩衝區溢位 | Nessus | SCADA | 2026/4/8 | high |
| 48337 | Windows ComputerSystemProduct 列舉 (WMI) | Nessus | Windows | 2026/4/8 | info |
| 47759 | Siemens SIMATIC WinCC 預設密碼驗證繞過 | Nessus | SCADA | 2026/4/8 | high |
| 45624 | Oracle RDBMS 主機名稱與修補程式資訊 | Nessus | Databases | 2026/4/8 | info |
| 45052 | WMI 防火牆列舉 | Nessus | Windows | 2026/4/8 | info |
| 45051 | WMI 防毒列舉 | Nessus | Windows | 2026/4/8 | info |
| 45050 | WMI 防間諜軟體列舉 | Nessus | Windows | 2026/4/8 | info |
| 44871 | WMI Windows 功能列舉 | Nessus | Windows | 2026/4/8 | info |