| 504026 | Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2019-17594) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504047 | Siemens SIMATIC S7-1500 Use After Free (CVE-2020-13871) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/2/14 | high |
| 504048 | Siemens SIMATIC S7-1500 Incorrect Conversion between Numeric Types (CVE-2021-27219) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504050 | Siemens SIMATIC S7-1500 Exposure of Resource to Wrong Sphere (CVE-2019-12904) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504052 | Siemens SIMATIC S7-1500 Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2024-52332) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504074 | Siemens SIMATIC and SCALANCE Improper Access Control (CVE-2025-1390) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504085 | Siemens SCALANCE, SIMATIC S7-1500 Generation of Error Message Containing Sensitive Information (CVE-2018-12886) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504089 | Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2019-3860) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504107 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2017-0663) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504113 | Siemens SIMATIC and SCALANCE Integer Overflow to Buffer Overflow (CVE-2025-0725) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504116 | Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2022-22823) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504122 | Siemens SIMATIC S7-1500 and Ruggedcom ROX Devices Out-of-bounds Read (CVE-2021-36087) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | low |
| 504144 | Siemens SIMATIC S7-1500 Cleartext Transmission of Sensitive Information (CVE-2021-22946) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504150 | Siemens SIMATIC S7-1500 Missing Encryption of Sensitive Data (CVE-2019-7309) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504153 | Siemens SIMATIC S7-1500 Use After Free (CVE-2020-8231) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504154 | Siemens SIMATIC S7-1500 NULL Pointer Dereference (CVE-2024-49881) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504167 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2019-17543) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504169 | Siemens SIMATIC S7-1500 Observable Discrepancy (CVE-2023-5981) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504171 | Siemens SIMATIC S7-1500 Improper Restriction of XML External Entity Reference (CVE-2013-0340) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504178 | Siemens SIMATIC S7-1500 Use After Free (CVE-2021-3518) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504184 | Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2021-3580) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504187 | Siemens SIMATIC S7-1500 Use of Insufficiently Random Values (CVE-2020-11501) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504193 | Siemens SIMATIC S7-1500 Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2017-7376) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504200 | Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2024-56570) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504207 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2019-18224) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504211 | Siemens SIMATIC S7-1500 Missing Encryption of Sensitive Data (CVE-2021-36690) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504215 | Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2022-25314) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504226 | Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2020-13434) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504228 | Siemens SIMATIC S7-1500 NULL Pointer Dereference (CVE-2024-56569) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504231 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2022-48522) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504232 | Siemens SIMATIC S7-1500 Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-3826) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504233 | Siemens SIMATIC and SCALANCE Multiple Releases of Same Resource or Handle (CVE-2025-0665) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504234 | Siemens SIMATIC S7-1500 Double Free (CVE-2021-22945) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504239 | Siemens SIMATIC S7-1500 Improper Resource Shutdown or Release (CVE-2019-6488) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504242 | Siemens SIMATIC S7-1500 Improper Check for Unusual or Exceptional Conditions (CVE-2019-19646) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504246 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2020-15358) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504247 | Siemens SIMATIC S7-1500 Improper Restriction of Recursive Entity References in DTDs (CVE-2023-52426) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504254 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2019-5482) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504258 | Siemens SIMATIC S7-1500 NULL Pointer Dereference (CVE-2018-14404) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504267 | Siemens SIMATIC S7-1500 Improper Limitation of a Pathname to a Restricted Directory (CVE-2023-27534) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504277 | Siemens SIMATIC S7-1500 Double Free (CVE-2019-5481) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504286 | Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2022-22822) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504287 | Siemens SIMATIC S7-1500 Missing Encryption of Sensitive Data (CVE-2023-34969) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504294 | Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2020-29363) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504295 | Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2019-3862) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504301 | Siemens SIMATIC S7-1500 Uncontrolled Resource Consumption (CVE-2023-32611) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504304 | Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2022-23990) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |
| 504323 | Siemens SIMATIC S7-1500 Always-Incorrect Control Flow Implementation (CVE-2024-56770) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | medium |
| 504324 | Siemens SIMATIC S7-1500 Loop with Unreachable Exit Condition (CVE-2017-16932) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | high |
| 504329 | Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2019-3858) | Tenable OT Security | Tenable.ot | 2025/11/13 | 2026/3/5 | critical |