83952 | Inductive Automation Ignition 多個弱點 | Nessus | SCADA | 2015/6/2 | 2025/7/14 | medium |
84263 | Schneider Electric InduSoft Web Studio < 7.1.3.4 多個資訊洩漏 (SEVD-2015-054-01) | Nessus | SCADA | 2015/6/18 | 2025/7/14 | medium |
85543 | Advantech WebAccess < 7.0-2011.08.27 多個 ActiveX RCE | Nessus | SCADA | 2015/8/19 | 2025/7/14 | medium |
85600 | Advantech WebAccess 7.2 < 7.2-2014.07.30 多個 ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2025/7/14 | medium |
85691 | Advantech WebAccess < 7.0-2009.06.29 多個弱點 | Nessus | SCADA | 2015/8/28 | 2025/7/14 | critical |
86572 | 3S CODESYS 運行時間工具組 < 2.4.7.48 PLCWinNT DoS (經認證的檢查) | Nessus | SCADA | 2015/10/23 | 2025/7/14 | medium |
86573 | 3S CODESYS 運行時間工具組 < 2.4.7.48 PLCWinNT DoS | Nessus | SCADA | 2015/10/23 | 2025/7/14 | medium |
88413 | iniNet SpiderControl PLC Editor Beckhoff 6.30.04 本機權限提升 | Nessus | SCADA | 2016/1/27 | 2025/7/14 | high |
88417 | iniNet SpiderControl SCADA Web 伺服器偵測 | Nessus | SCADA | 2016/1/27 | 2025/7/14 | info |
91283 | Moxa NPort Serial-to-Ethernet 伺服器偵測 | Nessus | SCADA | 2016/5/20 | 2025/7/14 | info |
97436 | Modicon Modbus/TCP 程式設計函式程式碼存取 | Nessus | SCADA | 2017/2/28 | 2025/7/14 | medium |
43614 | Netbiter Config NetbiterConfig.exe 裝置主機名稱遠端溢位 | Nessus | SCADA | 2009/12/30 | 2025/7/21 | high |
52992 | Movicon SCADA/HMI 軟體偵測 | Nessus | SCADA | 2011/3/25 | 2025/7/21 | info |
53223 | RealFlex Technologies RealWin 偵測 | Nessus | SCADA | 2011/3/30 | 2025/7/21 | info |
56994 | Advantech / BroadWin WebAccess webvrpcs.exe 服務遠端程式碼執行 (經認證的檢查) | Nessus | SCADA | 2011/12/2 | 2025/7/21 | critical |
65602 | Schneider Electric Accutech Manager 偵測 | Nessus | SCADA | 2013/3/18 | 2025/7/21 | info |
70292 | WellinTech KingView ActiveX 多個任意檔案覆寫弱點 | Nessus | SCADA | 2013/10/3 | 2025/7/21 | medium |
81298 | Siemens SIMATIC TIA Portal 偵測 | Nessus | SCADA | 2015/2/11 | 2025/7/21 | info |
84498 | Siemens SIMATIC ProSave 偵測 | Nessus | SCADA | 2015/7/2 | 2025/7/21 | info |
122424 | CODESYS V3 執行階段服務偵測 | Nessus | SCADA | 2019/2/26 | 2025/7/21 | info |
95713 | 已安裝 Siemens SINEMA Server | Nessus | SCADA | 2016/12/12 | 2025/7/21 | info |
23803 | National Instruments Lookout 偵測 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23807 | Siemens-Telegr ICCP 閘道偵測 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23823 | Modicon PLC CPU 類型 SNMP 要求模型類型遠端洩漏 | Nessus | SCADA | 2006/12/11 | 2025/7/25 | medium |
33201 | Vijeo Citect ODBC 伺服器遠端緩衝區溢位 | Nessus | SCADA | 2008/6/18 | 2025/7/21 | high |
133216 | Siemens SIMATIC STEP 7 的 TIA Portal 中有本機權限提升弱點 (SSA-629512) | Nessus | SCADA | 2020/1/24 | 2025/8/8 | high |
65195 | CoDeSys Gateway Service < 2.3.9.27 多個弱點 | Nessus | SCADA | 2013/3/11 | 2025/7/14 | critical |
84567 | Rockwell Automation MicroLogix 1100 PLC < Series B FRN 13.0 多個弱點 | Nessus | SCADA | 2015/7/7 | 2025/7/14 | critical |
83774 | WellinTech KingSCADA < 3.1.2.13-EN 'kxClientDownload.ocx' ActiveX RCE | Nessus | SCADA | 2015/6/1 | 2025/7/21 | high |
91385 | MicroLogix 1400 PLC Web 伺服器要求處理 RCE | Nessus | SCADA | 2016/5/31 | 2025/7/14 | critical |
77376 | CODESYS WAGO WebVisu 偵測 | Nessus | SCADA | 2014/8/25 | 2014/8/25 | info |
23805 | Siemens S7-SCL 開發工具偵測 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23806 | Telvent OASys 系統偵測 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23825 | Modicon PLC Modbus 從屬模式 SNMP 要求 Modbus 模式遠端洩漏 | Nessus | SCADA | 2006/12/11 | 2025/7/25 | medium |
149308 | CodeMeter 執行階段偵測 | Nessus | SCADA | 2021/5/6 | 2025/7/14 | info |
150962 | CodeMeter 執行階段緩衝區過度讀取 (WIBU-210423-01) | Nessus | SCADA | 2021/6/23 | 2025/7/14 | critical |
83302 | Modbus/TCP Report Slave ID | Nessus | SCADA | 2015/5/10 | 2025/7/14 | medium |
83467 | 使用中物件類別的 EtherNet/IP CIP 清單 | Nessus | SCADA | 2015/5/14 | 2025/7/14 | info |
83917 | WellinTech KingSCADA < 3.1.2.13-EN KAEClientManager Console 遠端驗證認證洩漏 | Nessus | SCADA | 2015/6/1 | 2025/7/14 | medium |
84499 | Siemens SIMATIC ProSave < 1300.100.2201.15 未受信任的路徑任意程式碼執行 (SSA-451236) | Nessus | SCADA | 2015/7/2 | 2025/7/14 | medium |
87124 | Emerson SM-Ethernet FTP 伺服器預設認證 | Nessus | SCADA | 2015/12/1 | 2025/7/14 | critical |
87125 | Emerson SM-Ethernet Web 介面預設認證 | Nessus | SCADA | 2015/12/1 | 2025/7/14 | high |
88839 | Advantech WebAccess openWidget 指令碼路徑遊走遠端檔案洩漏 | Nessus | SCADA | 2016/2/18 | 2025/7/14 | high |
90599 | Rockwell Automation MicroLogix 1400 PLC 預設認證 | Nessus | SCADA | 2016/4/20 | 2025/7/14 | critical |
91622 | Cogent DataHub < 6.4.3 OPC 用戶端重新連線飽和遠端 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
91624 | Cogent DataHub < 6.4.7 傳入的 DDE 連線處理遠端 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
99168 | Siemens S7 通訊協定支援偵測 | Nessus | SCADA | 2017/4/3 | 2025/7/14 | info |
100462 | GE Multilin UR / URPlus / B95Plus 保護轉送密碼編譯演算法弱點資訊洩漏 (UR-2017-0001) | Nessus | SCADA | 2017/5/26 | 2025/7/14 | critical |
100463 | GE Multilin UR / URPlus / B95Plus 轉送網頁介面偵測 | Nessus | SCADA | 2017/5/26 | 2025/7/14 | info |
120947 | 3S CODESYS Runtime 3.x < 3.5.14.0 存取控制不足弱點 | Nessus | SCADA | 2019/1/3 | 2025/7/14 | critical |