| 85600 | 7.2-2014.07.30 以前の Advantech WebAccess 7.2 の複数の ActiveX RCE | Nessus | SCADA | 2015/8/24 | 2025/11/3 | medium |
| 133216 | Siemens SIMATIC STEP 7におけるTIAポータルでのローカル権限昇格の脆弱性(SSA-629512) | Nessus | SCADA | 2020/1/24 | 2025/11/3 | high |
| 119147 | Modicon Quantum HTTPサーバーの「formTest」、「name」パラメーターを利用するXSS | Nessus | SCADA | 2018/11/26 | 2025/11/3 | medium |
| 23803 | National Instruments Lookout の検出 | Nessus | SCADA | 2006/12/11 | 2025/11/3 | info |
| 53877 | Samsung Data Management Server < 1.4.3 の verifyUser メソッドの SQL インジェクション | Nessus | SCADA | 2011/5/11 | 2025/11/3 | high |
| 65602 | Schneider Electric Accutech Manager 検出 | Nessus | SCADA | 2013/3/18 | 2025/11/3 | info |
| 70292 | WellinTech KingView ActiveX 複数の任意のファイル上書きの脆弱性 | Nessus | SCADA | 2013/10/3 | 2025/11/3 | medium |
| 73645 | Advantech WebAccess の Web 管理インターフェイス検出 | Nessus | SCADA | 2014/4/14 | 2025/11/3 | info |
| 83774 | WellinTech KingSCADA < 3.1.2.13-EN「kxClientDownload.ocx」ActiveX RCE | Nessus | SCADA | 2015/6/1 | 2025/11/3 | high |
| 85691 | Advantech WebAccess < 7.0-2009.06.29 複数の脆弱性 | Nessus | SCADA | 2015/8/28 | 2025/11/3 | critical |
| 91385 | MicroLogix 1400 PLC Web サーバーのリクエスト処理の RCE | Nessus | SCADA | 2016/5/31 | 2025/11/3 | critical |
| 95713 | インストールされたSiemens SINEMAサーバー | Nessus | SCADA | 2016/12/12 | 2025/11/3 | info |
| 109280 | Schneider Electric InduSoft Web Studio/InTouch Machine Edition Opcode 50 mbstowcs()のスタックオーバーフロー | Nessus | SCADA | 2018/4/23 | 2025/9/29 | critical |
| 23830 | OPC Historical Data Access (HDA) Server Detection | Nessus | SCADA | 2006/12/11 | 2025/7/14 | info |
| 57598 | GE D20 Default Credentials | Nessus | SCADA | 2012/1/19 | 2025/7/14 | high |
| 65194 | CoDeSys Unprotected Gateway Service | Nessus | SCADA | 2013/3/11 | 2025/7/14 | high |
| 72486 | Cogent DataHub < 7.3.4 Malformed POST Request Buffer Overflow RCE | Nessus | SCADA | 2014/2/13 | 2025/7/14 | high |
| 91284 | Moxa NPort Serial-to-Ethernet Server Multiple Vulnerabilities | Nessus | SCADA | 2016/5/20 | 2025/7/14 | critical |
| 33169 | CitectSCADA Detection | Nessus | SCADA | 2008/6/13 | 2023/5/24 | info |
| 72108 | Ecava IntegraXor < 4.1.4390 Buffer Overflow | Nessus | SCADA | 2014/1/21 | 2025/7/14 | high |
| 72107 | Ecava IntegraXor < 4.1.4369 Project Directory Information Disclosure | Nessus | SCADA | 2014/1/23 | 2025/7/14 | medium |
| 196950 | Rockwell FactoryTalk Historian < 9.01 DoS | Nessus | SCADA | 2024/5/14 | 2024/10/23 | high |
| 62439 | Magnum MNS-6K Hardcoded Admin Account | Nessus | SCADA | 2012/10/5 | 2025/7/14 | high |
| 52993 | Movicon < 11.2 Build 1084 Multiple Vulnerabilities | Nessus | SCADA | 2011/3/25 | 2025/7/14 | high |
| 59249 | 7-Technologies IGSS < 9.0.0.11291 DLL Loading Arbitrary Code Execution | Nessus | SCADA | 2012/5/23 | 2025/7/14 | high |
| 89030 | 7-Technologies IGSS < 9.0.0.11143 ODBC Invalid Structure RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
| 64630 | Ecava IntegraXor < 4.00.4283 ActiveX Remote Buffer Overflow | Nessus | SCADA | 2013/2/14 | 2025/7/14 | high |
| 89031 | 7-Technologies IGSS < 10.0.0 ODBC Buffer Overflow RCE | Nessus | SCADA | 2016/2/29 | 2025/7/14 | critical |
| 61493 | Sielco Sistemi Winlog Arbitrary File Disclosure | Nessus | SCADA | 2012/8/10 | 2025/7/14 | medium |
| 87891 | Janitza Multiple UMG Devices Remote Debug Interface RCE | Nessus | SCADA | 2016/1/13 | 2025/7/14 | high |
| 23809 | DNP3 Binary Inputs Access Remote Information Disclosure | Nessus | SCADA | 2006/12/11 | 2025/9/29 | medium |
| 70556 | Cogent DataHub Tunnel/Mirror Service Detection | Nessus | SCADA | 2013/10/23 | 2025/9/29 | info |
| 91345 | Allen-Bradley MicroLogix 1400 Multiple Vulnerabilities | Nessus | SCADA | 2016/5/27 | 2025/9/29 | critical |
| 213046 | Siemens TeleControl Server Basic Redundancy Server Detection | Nessus | SCADA | 2024/12/16 | 2025/9/29 | info |
| 89029 | 7-Technologies / Schneider-Electric IGSS ODBC Service Detection | Nessus | SCADA | 2016/2/29 | 2025/9/29 | info |
| 57602 | Sensitive information can be obtained from the GE D20 Remote Terminal Unit via TFTP | Nessus | SCADA | 2012/1/19 | 2025/9/29 | high |
| 70921 | Schneider Electric Accutech Manager 'RFManagerService' SQL Injection | Nessus | SCADA | 2013/11/15 | 2025/9/29 | critical |
| 72620 | TURCK BL20/BL67 Hardcoded Admin Account | Nessus | SCADA | 2014/2/10 | 2025/9/29 | critical |
| 81545 | Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836) | Nessus | SCADA | 2015/2/26 | 2025/9/29 | medium |
| 82665 | WellinTech KingView < 6.53 (2012-10-09) User Credentials Not Securely Hashed | Nessus | SCADA | 2015/4/9 | 2025/9/29 | low |
| 23811 | ICCP/COTP (ISO 8073) Protocol Detection | Nessus | SCADA | 2006/12/11 | 2025/9/29 | high |
| 112124 | Siemens Automation License Manager 6.x < 6.0.1 Directory Traversal | Nessus | SCADA | 2018/8/27 | 2025/10/7 | high |
| 53573 | Modbus/TCP Master OPC Server MODBUS Protocol Response Packet Remote Overflow | Nessus | SCADA | 2011/4/27 | 2025/7/14 | high |
| 127139 | 3S CODESYS V3 CmpUserMgr 3.x < 3.5.16.0 Password Transmission Vulnerability | Nessus | SCADA | 2019/8/12 | 2025/10/7 | high |
| 112123 | Siemens Automation License Manager 5.x < 5.3.4.4 Multiple Vulnerabilities | Nessus | SCADA | 2018/8/27 | 2025/10/7 | high |
| 58991 | RuggedCom RuggedOS Default 'factory' Account Backdoor | Nessus | SCADA | 2012/6/12 | 2025/10/20 | critical |
| 67144 | Tridium Niagara AX Web Server Multiple Vulnerabilities | Nessus | SCADA | 2013/7/3 | 2025/11/3 | high |
| 81789 | Siemens SIMATIC STEP 7 (TIA Portal) Detection | Nessus | SCADA | 2015/3/12 | 2025/11/3 | info |
| 58449 | 7-Technologies AQUIS Unspecified Path Subversion Arbitrary DLL Injection Code Execution | Nessus | SCADA | 2012/3/23 | 2025/11/3 | high |
| 70591 | KEPServerEX Detection | Nessus | SCADA | 2013/10/24 | 2025/11/3 | info |