84499 | Siemens SIMATIC ProSave < 1300.100.2201.15 不受信任的路径任意代码执行 (SSA-451236) | Nessus | SCADA | 2015/7/2 | 2025/7/14 | medium |
87124 | Emerson SM-Ethernet FTP 服务器默认凭据 | Nessus | SCADA | 2015/12/1 | 2025/7/14 | critical |
87125 | Emerson SM-Ethernet Web 界面默认凭据 | Nessus | SCADA | 2015/12/1 | 2025/7/14 | high |
88839 | Advantech WebAccess openWidget 脚本路径遍历远程文件泄露 | Nessus | SCADA | 2016/2/18 | 2025/7/14 | high |
90599 | Rockwell Automation MicroLogix 1400 PLC 默认凭据 | Nessus | SCADA | 2016/4/20 | 2025/7/14 | critical |
91622 | Cogent DataHub < 6.4.3 OPC 客户端重新连接饱和远程 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
91624 | Cogent DataHub < 6.4.7 传入的 DDE 连接处理远程 DoS | Nessus | SCADA | 2016/6/15 | 2025/7/14 | medium |
99168 | Siemens S7 协议支持检测 | Nessus | SCADA | 2017/4/3 | 2025/7/14 | info |
149308 | CodeMeter Runtime 检测 | Nessus | SCADA | 2021/5/6 | 2025/7/14 | info |
150962 | CodeMeter Runtime 缓冲区过度读取 (WIBU-210423-01) | Nessus | SCADA | 2021/6/23 | 2025/7/14 | critical |
100462 | GE Multilin UR / URPlus / B95Plus 保护中继加密算法弱点信息泄露 (UR-2017-0001) | Nessus | SCADA | 2017/5/26 | 2025/7/14 | critical |
100463 | GE Multilin UR / URPlus / B95Plus 中继 Web 界面检测 | Nessus | SCADA | 2017/5/26 | 2025/7/14 | info |
77375 | Honeywell FALCON XL Web 控制器多种漏洞 | Nessus | SCADA | 2014/8/25 | 2025/7/14 | high |
104101 | Schneider Electric InduSoft Web Studio < 8.0 SP2 Patch 1 不明远程命令执行 (LFSEC00000121) | Nessus | SCADA | 2017/10/23 | 2018/11/15 | critical |
117361 | Advantech WebAccess/SCADA Network Service 检测 | Nessus | SCADA | 2018/9/10 | 2025/7/21 | info |
23802 | 用于 ControlLogix 检测的 Matrikon OPC Server | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
52051 | Moxa Device Manager Tool MDM2_Gateway 响应远程溢出 | Nessus | SCADA | 2011/2/21 | 2025/7/21 | high |
59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll 模块操作码 3 数据包解析远程溢出 | Nessus | SCADA | 2012/6/5 | 2025/7/21 | critical |
59500 | WellinTech KingOPCServer 检测 | Nessus | SCADA | 2012/6/14 | 2025/7/21 | info |
59501 | WellinTech KingSCADA 检测 | Nessus | SCADA | 2012/6/14 | 2025/7/21 | info |
59502 | WellinTech KingSCADA 3.1 < 2012-04-16 user.db Base-64 编码本地凭据泄露 | Nessus | SCADA | 2012/6/14 | 2025/7/21 | high |
59558 | Measuresoft ScadaPro < 4.0.1.0 service.exe 多种漏洞(凭据检查) | Nessus | SCADA | 2012/6/18 | 2025/7/21 | critical |
66761 | Mitsubishi MX Component ActiveX 远程代码执行 | Nessus | SCADA | 2013/6/3 | 2025/7/21 | critical |
70415 | ProSoft RadioLinx ControlScape 安装检测 | Nessus | SCADA | 2013/10/14 | 2025/7/21 | info |
72556 | 3S CODESYS 2.x 开发系统检测(凭据检查) | Nessus | SCADA | 2014/2/18 | 2025/7/21 | info |
76573 | Triangle MicroWorks SCADA Data Gateway 检测(凭据检查) | Nessus | SCADA | 2014/7/17 | 2025/7/21 | info |
80910 | Honeywell OPOS Suite 堆栈缓冲区溢出 | Nessus | SCADA | 2015/1/22 | 2025/7/21 | high |
81107 | Schneider Electric 多种产品缓冲区溢出 | Nessus | SCADA | 2015/1/30 | 2025/7/21 | high |
81577 | Siemens SIMATIC WinCC (TIA Portal) V13 检测 | Nessus | SCADA | 2015/3/1 | 2025/7/21 | info |
88412 | iniNet SpiderControl SCADA Editor 检测 | Nessus | SCADA | 2016/1/27 | 2025/7/21 | info |
90001 | PACTware 检测 | Nessus | SCADA | 2016/3/17 | 2025/7/21 | info |
91625 | Panasonic Control FPWIN Pro 检测 | Nessus | SCADA | 2016/6/15 | 2025/7/21 | info |
95714 | Siemens SINEMA Server < 13 SP2 无引号服务路径本地权限提升 (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2025/7/21 | medium |
77376 | CODESYS WAGO WebVisu 检测 | Nessus | SCADA | 2014/8/25 | 2014/8/25 | info |
23805 | Siemens S7-SCL 开发工具检测 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23806 | Telvent OASys 系统检测 | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23825 | Modicon PLC Modbus 从属模式 SNMP 请求 Modbus 模式远程泄露 | Nessus | SCADA | 2006/12/11 | 2025/7/25 | medium |
200986 | Rockwell Automation ThinManager ThinServer Improper Input Validation (CVE-2024-5990) | Nessus | SCADA | 2024/6/25 | 2024/10/23 | high |
124591 | Advantech WebAccess webvrpcs.exe 0x138bd IOCTL RCE | Nessus | SCADA | 2019/5/3 | 2025/7/21 | critical |
126469 | Advantech WebAccess webvprcs IOCTL 10012 Stack Overflow | Nessus | SCADA | 2019/7/4 | 2025/7/21 | critical |
129292 | Advantech WebAccess webvprcs IOCTL 70603 Stack Overflow | Nessus | SCADA | 2019/9/24 | 2025/7/21 | critical |
174565 | RoboDK Installed (Windows) | Nessus | SCADA | 2023/4/20 | 2025/7/21 | info |
205315 | Johnson Controls exacqVision Web Server Installed (Windows) | Nessus | SCADA | 2024/8/9 | 2025/7/21 | info |
206205 | Johnson Controls exacqVision Client Installed (Windows) | Nessus | SCADA | 2024/8/26 | 2025/7/21 | info |
23799 | Areva/Alstom Energy Management System Detection | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23800 | Matrikon OPC Server for Modbus Detection | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
23828 | OPC Application Components Detection | Nessus | SCADA | 2006/12/11 | 2025/7/21 | info |
49694 | BACnet OPC Client < 1.0.25 Buffer Overflow | Nessus | SCADA | 2010/9/24 | 2025/7/21 | high |
53548 | Ecava IntegraXor Detection | Nessus | SCADA | 2011/4/25 | 2025/7/21 | info |
58450 | 7-Technologies TERMIS Detection | Nessus | SCADA | 2012/3/23 | 2025/7/21 | info |