搜尋 Plugin

ID名稱產品系列已發布已更新嚴重性
500443Rockwell Automation Allen-Bradley Micrologix 1100 Improper Handling of Length Parameter Inconsistency (CVE-2020-6111)Tenable OT SecurityTenable.ot2022/2/72026/9/21
high
500444Emerson DeltaV Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2012-3035)Tenable OT SecurityTenable.ot2022/2/72026/4/21
high
500452Emerson DeltaV Improper Permissions, Privileges, and Access Controls (CVE-2016-9345)Tenable OT SecurityTenable.ot2022/2/72026/9/21
medium
500470Yokogawa CENTUM Improper Authentication (CVE-2020-5608)Tenable OT SecurityTenable.ot2022/2/72026/6/21
critical
500495Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-5666)Tenable OT SecurityTenable.ot2022/2/72026/9/21
high
500500Mitsubishi Electric MELSEC iQ-R Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2020-5653)Tenable OT SecurityTenable.ot2022/2/72024/9/4
critical
500504Siemens OpenSSL in Industrial Products (CVE-2021-3449)Tenable OT SecurityTenable.ot2022/2/72025/3/10
medium
500520Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Plaintext Storage of a Password (CVE-2019-14929)Tenable OT SecurityTenable.ot2022/2/72024/12/5
critical
500533Siemens PROFINET Devices Allocation of Resources Without Limits or Throttling (CVE-2020-28400)Tenable OT SecurityTenable.ot2022/2/72025/3/10
high
500534Mitsubishi Electric SmartRTU Forced Browsing (CVE-2018-16060)Tenable OT SecurityTenable.ot2022/2/72024/12/18
high
500537Mitsubishi Electric MELSEC iQ-R Improper Access Control (CVE-2020-5656)Tenable OT SecurityTenable.ot2022/2/72026/9/21
critical
500538Mitsubishi Electric MELSEC-F Series Null Pointer Dereference (CVE-2021-20596)Tenable OT SecurityTenable.ot2022/2/72026/9/21
high
500547Siemens Nucleus RTOS-based APOGEE and TALON Products Improper Validation of Specified Quantity in Input (CVE-2021-31346)Tenable OT SecurityTenable.ot2022/2/72025/12/6
critical
500554Mitsubishi Electric MELSEC iQ-R Null Pointer Dereference (CVE-2020-5655)Tenable OT SecurityTenable.ot2022/2/72026/9/21
high
500563Siemens Nucleus RTOS-based APOGEE and TALON Products Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2021-31883)Tenable OT SecurityTenable.ot2022/2/72025/12/6
high
500567Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Incorrect Default Permissions (CVE-2019-14925)Tenable OT SecurityTenable.ot2022/2/72024/12/5
medium
500572Siemens Nucleus RTOS-based APOGEE and TALON Products Buffer Access with Incorrect Length Value (CVE-2021-31885)Tenable OT SecurityTenable.ot2022/2/72025/12/6
high
500585Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2021-20591)Tenable OT SecurityTenable.ot2022/2/72026/9/21
high
500593Siemens Nucleus RTOS-based APOGEE and TALON Products Improper Validation of Specified Quantity in Input (CVE-2021-31345)Tenable OT SecurityTenable.ot2022/2/72025/12/6
critical
500599Schneider Electric Modicon Out-of-bounds Read (CVE-2021-22790)Tenable OT SecurityTenable.ot2022/2/72023/11/20
medium
500600Mitsubishi Electric MELSEC and MELIPC Denial Of Service (CVE-2020-5531)Tenable OT SecurityTenable.ot2022/2/72026/9/21
critical
500625Yokogawa CENTUM and Exaopc Use of Hard-Coded Credentials (CVE-2022-23402)Tenable OT SecurityTenable.ot2022/3/302026/9/21
critical
500629Siemens SICAM A8000 Missing Authentication For Critical Function (CVE-2022-27480)Tenable OT SecurityTenable.ot2022/4/192024/11/27
high
500638Schneider Electric Relative Path Traversal in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25176)Tenable OT SecurityTenable.ot2022/4/282024/9/4
critical
500640Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information (CVE-2020-25178)Tenable OT SecurityTenable.ot2022/4/282026/4/21
high
500645Mitsubishi Electric FA Products Cleartext Storage of Sensitive Information (CVE-2022-25158)Tenable OT SecurityTenable.ot2022/4/282024/9/4
critical
500647Schneider Electric Use of Hard-Coded Cryptographic Key in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25180)Tenable OT SecurityTenable.ot2022/4/282026/9/21
medium
500664Siemens CPC80 Firmware of SICAM A8000 Missing Release of Resource After Effective Lifetime (CVE-2022-29884)Tenable OT SecurityTenable.ot2022/7/192025/3/10
high
500665Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22714)Tenable OT SecurityTenable.ot2022/7/212024/12/5
critical
500666Wago 750-8XX series Improper Authentication (CVE-2020-12505)Tenable OT SecurityTenable.ot2022/7/212024/12/5
critical
500677Siemens SCALANCE X Switch Devices Buffer Copy Without Checking Size of Input (CVE-2022-26649)Tenable OT SecurityTenable.ot2022/7/212025/3/10
critical
500678Siemens SCALANCE X Switch Devices Use of Insufficiently Random Values (CVE-2022-26647)Tenable OT SecurityTenable.ot2022/7/212025/3/10
high
500679Wago IO 750-849 & 750-881 No Privilege Separation (CVE-2015-6473)Tenable OT SecurityTenable.ot2022/7/212026/9/21
critical
500681Siemens SRCS VPN Feature in SIMATIC CP Devices Improper Control of Generation of Code (CVE-2022-34821)Tenable OT SecurityTenable.ot2024/3/222026/9/21
critical
500684Schneider Electric Modicon Exposure of Resource to Wrong Sphere (CVE-2022-34765)Tenable OT SecurityTenable.ot2022/7/212026/4/21
medium
500689Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2022-34763)Tenable OT SecurityTenable.ot2022/7/272026/4/21
high
500691Schneider Electric Modicon Path Traversal (CVE-2022-34762)Tenable OT SecurityTenable.ot2022/7/282026/4/21
high
500715Siemens Web Server Login Page of Industrial Controllers Cross-Site Request Forgery (CVE-2022-30694)Tenable OT SecurityTenable.ot2022/12/162025/6/26
medium
500721Siemens Multiple Denial of Service in Industrial Products (CVE-2021-40365)Tenable OT SecurityTenable.ot2023/1/52025/3/10
high
500729Siemens SCALANCE X Authentication Bypass (CVE-2019-13933)Tenable OT SecurityTenable.ot2023/1/252024/9/4
high
500730Siemens Desigo PXC and DXR Devices Improper Restriction of Excessive Authentication Attempts (CVE-2022-24044)Tenable OT SecurityTenable.ot2023/1/252024/9/4
high
500734Siemens SCALANCE X-300 Switches Buffer Copy Without Checking Size of Input (CVE-2022-26334)Tenable OT SecurityTenable.ot2023/1/252025/3/10
high
500744Siemens Desigo PXC and DXR Devices Insufficient Session Expiration (CVE-2022-24042)Tenable OT SecurityTenable.ot2023/1/252024/11/26
critical
500749Siemens in SCALANCE Products (CVE-2022-46140)Tenable OT SecurityTenable.ot2023/1/252026/8/31
medium
500758Siemens SCALANCE X-300 Switches Stack-Based Buffer Overflow (CVE-2022-25753)Tenable OT SecurityTenable.ot2023/1/252025/3/10
high
500761Siemens Desigo PX Devices External Control of Assumed-Immutable Web Parameter (CVE-2019-13927)Tenable OT SecurityTenable.ot2023/1/252024/9/4
medium
500764Siemens Web Server of SCALANCE X200 Heap-Based Buffer Overflow (CVE-2021-25668)Tenable OT SecurityTenable.ot2023/1/252026/6/21
critical
500768Siemens SCALANCE Improper Neutralization of Script-Related HTML Tags in a Web Page (CVE-2022-36325)Tenable OT SecurityTenable.ot2023/1/252026/4/28
medium
500771Siemens Desigo PXC and DXR Devices Use of Password Hash with Insufficient Computational Effort (CVE-2022-24041)Tenable OT SecurityTenable.ot2023/1/252024/11/26
medium
500785Siemens Desigo PXC and DXR Devices Uncontrolled Resource Consumption (CVE-2022-24040)Tenable OT SecurityTenable.ot2023/1/252026/9/21
medium